What we do.

We develop creative, comprehensive, and sustainable engineering solutions for a future where society can thrive.

Power Management and Quality Monitoring

Masterpact Techno-Solution, Inc. specializes in power management and quality monitoring to enhance system performance, reduce energy costs, and maintain high standards of electrical reliability.

pm&qm-1
POWER QUALITY MONITORING
A semiconductor company focused on the design, fabrication, assembly, and testing of integrated circuit must have the right power quality at all times. And as a manufacturing facility that has a contract to local power distributor, a power quality meter with a monitoring server is crucially needed for power quality monitoring and interruption event logger. CET’s iMeter 7A with PecStar iEMS software is the best solution for power quality monitoring with interruption event logger. The iMeter 7A complies with modern power quality standards and has programmable setpoints for local setpoint standards combined with the iEMS software’s capability to log different kinds of interruption events. The client is satisfied by the solution and has decided to integrate existing meters to the monitoring server for a centralized power monitoring server.
UTILITY BILLING
A 32-floor corporate center building has numerous clients catering different office spaces for various companies. An organized power monitoring server is needed for accurate power billing to their clients. PecStar iEMS Software paired with PMC-53A meters are the best solution for organizing power billing for all their clients. iEMS software offers accuracy, practicality, and efficiency in gathering data and report generation for automatic computation of power billing set specifically every certain day of every month. With the advanced PMC-53A power meter, the client is assured that the system gives accurate power billing to all their clients, satisfied enough that we installed 163 power meters in total.
pm&qm-2
pm&qm-3
POWER QUALITY MONITORING
An automotive manufacturing facility is focused on fabricating and assembling automotive parts for vehicle production. With different departments it is hard to determine the load being consumed by each department. Load monitoring and control is severely needed for load side management to boost efficiency. PecStar iEMS Software together with PMC-53A, PMC-53M-A, and PMC-53A-E are the most cost effective solution for monitoring accurate load consumption. iEMS software offers accuracy, practicality, and efficiency in gathering and presenting data. With the advanced power meters that are installed, the management can accurately determine and implement strategic ways to be a more efficient facility by applying load side management.

PMC-S963

  • Three-Phase Multifunction Meter
  • IEC62053-22 Class 0.5S
  • DIN96 (92x92mm Cutout)
  • Backlit B&W LCD Display
  • Harmonics, Demands, Max/Min Log, Setpoint Alarms and Event Log
  • 4xDI, optional 2xDO and 1xSS Output
  • AO application (S963-C only)
  • 1xEthernet, 1xRS-485 (S963–E)
  • 1xRS-485 (S963–C)

PMC-53A-E

  • Three-Phase Multifunction Meter
  • IEC62053-22 Class 0.5S
  • DIN96 (92x92mm Cutout)
  • Backlit Dot-Matrix LCD Display
  • Harmonics, Demands & TOU, Energy Log, Max/Min Log and Event Log
  • Waveform Capture on Screen
  • Modbus RTU, TCP, HTTP, SNTP, SMTP, TFTP, BACnet, DNP3.0
  • 1xEthernet, 1xRS-485
  • 4xDI, 2xDO, 1xI4, 1xIr and 1xAI

PMC-53A

  • Low-Cost Three-Phase Multifunction Meter
  • IEC62053-22 Class 0.5S
  • DIN96 (92x92mm Cutout)
  • Backlit Dot-Matrix LCD Display
  • Harmonics, Demands & TOU, Energy Log,
  • Max/Min Log and Event Log
  • Waveform Capture on Screen
  • Modbus RTU, BACnet MSTP, Metasys N2 or DNP
  • 1xRS-485 + 2nd RS-485(Optional)
  • Optional 4xDI, 2xRO/DO, Optional I4, RTD

PMC-53M-A

  • Three-Phase Multifunction Meter
  • IEC62053-22 Class 0.5S
  • DIN96 (92x92mm Cutout)
  • Backlit B&W LCD Display
  • Harmonics, Demands, Max/Min Log, Setpoint Alarms and Event Log
  • Modbus RTU
  • 1xRS-485
  • Optional 4xDI, 2xDO

iMeter 8

  • Advanced Power Quality Analyzer
  • IEC 62053-22 Class 0.2S, IEC61000-4-30 Ed. 3.1 Class A Certified
  • DIN192 (186x186mm Cutout)
  • Colour TFT LCD Display
  • Harmonics, Demands & TOU, PQ Log, Energy Log, Max/Min Log, Waveform Log and Event Log
  • 8GB On-board Memory
  • 2-150kHz Conducted Emission, GPS, IRIG-B
  • Modbus RTU, Modbus TCP, HTTPS, SNTP, SMTP, FTP, IEEE1588 (PTP), Ethernet Gateway, IEC61850
  • 2xEthernet, 2xRS-485
  • 8x/16xDI, 4x/8xDO, 4xSS Pulse Outputs, Optional 2xAI, 1xAO

iMeter 7A

  • PQ monitoring at HV, MV and LV Utility Substations
  • IEC 62053-22 Class 0.2S, IEC61000-4-30 Ed. 3.1 Class A Certified
  • Data Centers, Semiconductor Fabs, Heavy Industries
  • Renewable Energy Applications
  • 7x24 Automated Manufacturing Facilities
  • Dips/Swells/Interruptions, Transients, Flickers & Harmonics Monitoring
  • Mains and critical feeder monitoring
    IEC 61850 support for Substation Automation and Smart Grid
  • Retrofit applications with optional Class 0.5S Split-Core Current Probes (SCCPs)

iMeter D7

  • Advanced Power Quality Analyzer
  • IEC 62053-22 Class 0.2S, IEC61000-4-30 Ed. 3 Class A Certified
  • 35mm DIN Rail (145x124x77mm)
  • Colour IPS Dot-Matrix Display
  • Harmonics, Demands & TOU, PQ Log, Energy Log, Max/Min Log, Waveform Log and Event Log
  • 4GB On-board Memory
  • 2-150kHz Conducted Emission, MQTT
  • Modbus RTU, Modbus TCP, HTTPS, SNTP, SMTPS, FTP, IEEE1588 (PTP), IPSecVPN, MQTT, Ethernet Gateway, IEC61850
  • 2xEthernet, 1xRS-485, Optional built-in 4G modem
  • 4xDI, Optional 3xDO, 3xSS, 2xAI, 1xIr, 1xRTD

iMeter 6

  • Advanced Power Quality Monitor
  • IEC 62053-22 Class 0.2S, IEC61000-4-30 Ed. 3 Class S Compliant
  • DIN96 (92x92mm Cutout)
  • Colour IPS Dot-Matrix Display
  • Harmonics, Demands & TOU, PQ Log, Energy Log, Max/Min Log, Waveform Log and Event Log
  • 2GB On-board Memory
  • Modbus RTU, Modbus TCP, HTTPS, SNTP, SMTPS, FTPS, SNMP, BACnet/IP, Ethernet Gateway, IEC61850
  • 1xEthernet, 1xRS-485
  • 6xDI, 3xDO, Optional 1xAI

PecStar® iEMS

  • Industrial and Utility SCADA
  • Substation Automation for Industrial and Utility Applications Energy Management for Industrial Facilities and Commercial Buildings Low-voltage Motor Control Centre for Industrial Applications
  • Electrical Fire Monitoring for Commercial Buildings and Shopping Centres
  • Power Quality Monitoring for Utilities, Industrial Facilities, Data Centres and Mission Critical Applications